Equipment Guide · Rinnai

Rinnai Boiler Equipment & Error Codes

Technical specifications, platform control notes, and complete error code lookup table for Rinnai boilers.

Platform & Control Notes

I-Series condensing combi and solo boilers use E:### codes. Normal system pressure on these runs ~17–26 psi. (Rinnai tankless water heaters use a different code set — ask us if that's what you have.)

Model Families & Platforms

  • I-Series Condensing Combi (i060c, i090c, i120c)
  • I-Series Condensing Solo (i060s, i090s, i120s)

Diagnostic Characteristics & Common Service Topics

Rinnai boilers utilize specific display codes and safety lockouts to protect the heat exchanger, combustion system, and hydronic loop. Everyday issues like pressure loss, flame sensing errors, or circulator faults trigger specific responses depending on the controller generation.

Sample Fault Code Summaries from Vault Records
CodeMeaningAction Required
E:100Air supply or exhaust blockage / condensate trap full.Safely check that outdoor intake/exhaust terminations are clear of snow, ice, leaves, or debris. If clearing them doesn't resolve it, or the condensate trap needs service, call a licensed pro.
E:110No ignition — burner failed to light.Verify the manual gas valve is open and (propane) the tank isn't empty, then one reset. If it won't light or recurs, stop and call a pro.
E:120Flame failure — flame was established but then lost.Confirm gas is fully on, then one reset. Flame-sensing/combustion faults need a tech with a combustion analyzer — if it doesn't clear, call a pro.
E:140Heat exchanger overheat.Check that pressure reads in the normal 17–26 psi band. Overheat usually means a flow problem — call a licensed pro. Don't keep resetting an overheating boiler.
E:190Electrical grounding fault.Not a homeowner repair. Confirm the boiler is on a properly grounded, correctly wired outlet (no extension cords/adapters). Call a licensed pro or electrician.
E:430High or low water pressure in the heating system.Read the gauge — normal cold range is ~17–26 psi. Adding water or checking the expansion tank should be done by your installer. Repeated low pressure usually means a leak — call a pro.
E:443Low Water Cut Off (LWCO) activated.An LWCO trip means the boiler shut down for safety. Don't fire it dry. Check for visible leaks and call a licensed pro to find the cause and refill/bleed correctly.
E:540High exhaust (flue gas) temperature.A combustion/heat-exchanger issue — not a homeowner repair. Call a licensed pro to inspect the heat exchanger, venting, and combustion.

Complete Error Code Library

For the complete searchable error-code lookup table for Rinnai equipment (including all 11 codes, exact lockout causes, and technician actions), visit the Phillips Hydronics Error Code Library.

Related Symptom & Diagnostic Guides

Sources & Documentation

  • error-codes.json — https://media.rinnai.us/salsify_asset/s-c1e4cb84-0b9d-4c3b-9c5b-9749d8dd9b10/800000114-I-Series%20Condensing%20Combi%20Boiler%20User%20Manual.pdf